close

DVT Series DC Voltage Transformer

Output Voltage Proportional to the DC Input Voltage

DIN Mounted- Isolated

vdc-to-vdc

One moment…we are redirecting you to our partner, Aim Dynamics. https://www.aimdynamics.com/

Magnelab Aimdynamics

Back to Magnelab

Buy Now
Via Distribution
We offer the best of both worlds

Quick turn-around of smaller quantities, as well as larger volume competitive pricing. Our offshore advantages include the lowest labor costs in the Western hemisphere, making our pricing competitive with suppliers anywhere!

An ISO 9001:2015 certified company

Features:
• Primary DC Transducer Voltage range: 15-1500Vdc, 10-1000Vdc or 1-100Vdc
• Output 4-20mA, 0-1Vdc or 0-5Vdc
• Accuracy: ±1% over range, Linearity: 0.5% over range
• Response time: 10 mSec, Working Range: 0–120%
• Overload: 150% continuous, Isolation: 4.5KV, 1 minute
• Supply voltage: 15–36Vdc

Description:
The DVT Series by Magnelab is also known as the DVT-100 DIN rail mounted isolated DC voltage transducer. The voltage transformer has been designed to convert a voltage input of 15-1500 Vdc, 10-1500 Vdc or 1-100 Vdc to either a 4-20mA output or a voltage standard output of 0 to 1 Vdc or 0 to 5 Vdc. It can be used to convert to a voltage standard output that is suitable for and proportional to the output. This DVT voltage sensor is also often used in solar string voltage monitoring. This is because it is a safe and effective device to isolate the input and the output.

The DVT-1500-420 voltage transducer is part of this DVT series. This is the specific voltage transformer that has an output of 4-20 mA and with an input of up to 1500 Vdc. It has a 0.5% accuracy over its range and 0.2% linearity over the range. The response time is as short as 10.0 ms and it has a working range of between 1 and 120%. Overload capability is a continuous 150% and it can operate within the temperature range of -35 degrees Celsius to 100 degrees Celsius. This voltage transformer can operate in environments with relative humidity up to 90%. The isolation is 4.5 Kv in one minute and the device’s supply voltage is between 15 and 36 Vdc. It also comes with a full seven year warranty. It also fully conforms to UL508C, as well as being CSA C22.2 certified. This is a testament to the safety and efficiency of the DVT series voltage sensors.

Specifications

PART NUMBER AND RATING
DVT-1500-420 In 1500V Out 4-20mA
DVT-1500-V01 In 1500V Out 0-1Vdc
DVT-1500-V05 In 1500V Out 0-5Vdc
DVT-1000-420 In 1000V Out 4-20mA
DVT-1000-V01 In 1000V Out 0-1Vdc
DVT-1000-V05 In 1000V Out 0-5Vdc
DVT-100-420 In 100V Out 4-20mA
DVT-100-V05 In 100V Out 0-5Vdc
All Dimensions in Inches
H 2.32"
W 0.71"
L 3.72"

SHOW MORE PRODUCTS