HFCT Current Transformer Broad Frequency Response

Frequency Response up to 500 MHz

Measurement range up to 20kA

aac-to-vac

We offer the best of both worlds

Quick turn-around of smaller quantities, as well as larger volume competitive pricing. Our offshore advantages include the lowest labor costs in the Western hemisphere, making our pricing competitive with suppliers anywhere!

An ISO 9001:2015 certified company

High Frequency Current Transformer

The Magnelab high frequency current transformer (HFCT) – designed to provide a very accurate, non contact, non destructive measurement of either a single or a repetitive bipolar or unipolar pulse. Furthermore, it contains a solid toroid core and will measure input ranges of 200 to 20,000 amps DC or 2 to 71 amps AC. It comes with opening sizes from 1/4 to 2 inches. In addition, it’s voltage output ranges from 0.025 to 5.0 V/A. It also works for the continuous wave.

Broad Frequency Response

The AC current sensors in this series measures current from just microamperes up to 20,000 amperes. These are broad frequency response CTs that can operate from just 0.5 Hz to 500 MHz. The devices come in five different case sizes and you will choose between an SMA or a BNC connector type.

Another high accuracy CT is the HT-300M Hall effect current transducer. This has a fast response and provided with a 3 kV proof stress. Unlike the HFCT, which measures AC current, the HT-300M measures DC current of up to 300 amperes.

High Sensitivity

The HFCT has a very high frequency cutoff, which ensures that fast transients can be faithfully rendered. Additionally, it has an operating temperature of between minus 20 degrees Celsius and plus 120 degrees Celsius. Its nominal accuracy is also much better, standing at 0.5% that is spread over a wider bandwidth. The Magnelab HFCT is also as much as five times more sensitive to signal measurement at low intensity. Applications for the HFCT include electromagnetic interference research, power system harmonics and transients, laser and plasma research, corona wire discharge, semiconductor gate switching, and partial discharge measurement.

Click here for Operational and Installation Guide.

Features

  • Higher frequency cutoff, assuring faithful rendering of fast transients
  • Up to five times more sensitive for low intensity signal measurement
  • Operation temperature -20 degree C to plus 120 degree C
  • Higher nominal accuracy ±0.5% over a wider bandwidth

Click on the red button above to view the SPEC Sheet on this product.

Specifications

SIZE OPTIONS
B 0.25" Opening
C 0.5" Opening
D 1.0" Opening
E 1.5" Opening
F 2.0" Opening

			